New standalone installation of Sophos Anti-Virus fails to update from Sophos with the error:
"Could not find a source for updated packages"
Issue recently discovered by Sophos technical support and can be caused by using an outdated installer.
To resolve:
Uninstall Sophos Anti-Virus and AutoUpdate.
Reboot and delete C:\ProgramData\Sophos.
Reinstall using latest 10.3.11 installer from Sophos.
Filename: savw_103_sa_sfx.exe
CRC-32: fabe7e15
MD4: 1a9b80eb474e4d4f67ff6fe996d0d1be
MD5: cfb24eaeaa380fd1be58c0729c1b6977
SHA-1: ebf7327c6ef81c0a8ec9ba7e48ddc09327a76295
Monday, 26 October 2015
Thursday, 22 October 2015
Microsoft Outlook 2016: 0x800CCE05 Error
Outlook 2016 on Windows 10 displays 0x800cce05 when attempting to add IMAP account. This can be caused by a previously version of Office, Office 365 installation or conflict with Windows 10.
To resolve right click the Start button, select Command Prompt (Admin) and enter:
sfc /scannow
C:\Windows\system32>sfc /scannow
Beginning system scan. This process will take some time.
Beginning verification phase of system scan.
Verification 100% complete.
Windows Resource Protection found corrupt files and successfully repaired
them. Details are included in the CBS.Log windir\Logs\CBS\CBS.log. For
example C:\Windows\Logs\CBS\CBS.log. Note that logging is currently not
supported in offline servicing scenarios.
To resolve right click the Start button, select Command Prompt (Admin) and enter:
sfc /scannow
C:\Windows\system32>sfc /scannow
Beginning system scan. This process will take some time.
Beginning verification phase of system scan.
Verification 100% complete.
Windows Resource Protection found corrupt files and successfully repaired
them. Details are included in the CBS.Log windir\Logs\CBS\CBS.log. For
example C:\Windows\Logs\CBS\CBS.log. Note that logging is currently not
supported in offline servicing scenarios.
Tuesday, 20 October 2015
Bentley Hevacomp: Run-time Error 76 Path not found
Run-time error '76': Path not found is displayed when browsing for a project in Bentley Hevacomp.
Review PATHS.dat in C:\Hevacomp Projects and verify file path is correct and accessible.
Browse to file location, open Projects.ndx in Notepad and verify file path is correct and accessible.
"V1"
"S:\Hevacomp Projects\","\","\"
Review PATHS.dat in C:\Hevacomp Projects and verify file path is correct and accessible.
Browse to file location, open Projects.ndx in Notepad and verify file path is correct and accessible.
"V1"
"S:\Hevacomp Projects\","\","\"